Adding A Second Zone Of Heat In Attic
The zone control panel is the central control that will communicate between thermostats dampers and your hvac equipment.
Adding a second zone of heat in attic. You can build an insulated mechanical room in your attic if you want. But by adding powered attic fans you will draw more air into the attic. 2 improving ventilation in the attic and or insulating the attic floor to minimize the effect of attic heat and cold in the two season on the upper floor. During a major energy upgrade that we recently completed we had two return ducts a 14 in the main house and a 12 return duct in the master bedroom.
Blake shurtzmuch like the recommendation to install dampers i almost always emphasize adding a second return when replacing ductwork. Attic hvac systems save space. This solution doesn t address the ductwork so it is an inferior solution compared to creating an unvented conditioned attic. You should only add zones if you re still not comfortable after optimizing the building envelope.
In other words seal air leaks and increase insulation first. So why put an hvac system up in the attic at all. Most updated central air conditioned homes have a new air conditioner split system meaning the ac is broken up into parts. Using insulation only keeps the attic s heat from traveling through your home.
The thermostat will usually start at 95 degrees fahrenheit which is the temperature that the attic fan usually starts at. It will help to keep the attic much cooler in the summertime. Most homeowners who build an insulated mechanical room in their attic make the room too small. 1 installing a manual or electrically controlled which uses second thermostat to control it damper valve in the ducting to regulate the percentage of airflow going to each area.
That was for a 1 5 ton system and the static was 0 33 inches of water column iwc. Adding a zone or two is a smart choice on some occasions but not always. The cost of a dual zone system depends on your hvac contractor but a ballpark figure would be around 2 500 3 500 if it is done during an installation depending on the size of your house and your area. Several issues to consider.
Well mainly it s a way to save space. It is mounted by your equipment and is the brains of the entire zoning application. If the temperature is too cold or too hot for your liking the thermostat. And the extra heat is not just a summer concern come winter hot attic air can melt snow on the roof during the day only to refreeze when temperatures drop overnight creating ice dams that lead.
We went with.