2015 Ibc Attic Ventilation Requirements
Ventilation openings having a least dimension larger than 1 4 inch 6 4 mm shall be provided with corrosion resistant wire cloth screening hardware cloth perforated vinyl or similar material with openings having a least dimension of 1 16 inch 1 6 mm minimum and 1 4 inch 6 4 mm maximum.
2015 ibc attic ventilation requirements. To this end the 2015 version of the international building code ibc includes new provisions that relate to unvented enclosed rafter truss assemblies and unvented attics. Pdf 2015 international residential code for attic ventilation 145 kb. 1203 2 ventilation required enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof framing members shall have cross ventilation for each separate space by ventilation openings protected against the entrance of rain and snow. The net free cross ventilation area shall be permitted to be reduced to 1 300 provided that not less than 50 percent and not more than 80 percent of the required ventilating area provided by ventilators located in the upper portion of the space to be ventilated at least 3 feet 914 mm above eave or cornice vents with the balance of the required ventilation provided by eave or cornice vents.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures. The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures. Exception 1 allows you to only ventilate 1 300 th of the attic area if 50 to 80 of the ventilation occurs at least 3 above eave or cornice vents. Furthermore nrca also rec ommends the amount of ventila tion in static ventilation systems.
2015 international residential code for attic ventilation the code minimum ratio is 1 150. For large volume attics such as where roof slopes are greater than 8 12 designers also should consider increasing the amount of attic ventilation to account for the additional volume of attic space. Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain or snow. The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
These rules especially in section 1203 3 unvented attic and unvented enclosed rafter assemblies dictate how design professionals specify vapor retarders and. Ibc 1203 2 requires 1 150 th of the attic area to be ventilated but there is an exception that is commonly used instead.